BiT 1000®solar H1Z2Z2-K PV

Flexible single-conductor cables, for photovoltaic systems, acc. to EN 50618, IEC 62930

Indoor application Indoor application
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
High flexibility High flexibility
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)

Basic

  • Type: Control and power cables
  • Operating voltage: 0,6/1 kV
  • Voltage test: 1500 V
  • Insulation resistance: 1500 MΩ/km

Operating temperature

  • Minimum installation temperature: -15°C

Cable construction

  • Conductor material: tinned copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: LSOH
  • Core arrangement: single-core cable
  • Sheath type: LSOH
  • Sheath color: red, black

Fire and functional properties

  • Halogen-free, Low smoke emission EN 61034

Flame retardant

  • For a single insulated cable

Installation conditions

  • Internal application
  • External application
  • Underground installation
  • Flexible connections

Environmental resistance

  • O3 – wysoka olejoodporność
  • Oil resistant EN 60811-404
  • UV resistance

Additional elements

  • Damp proof barrier

BiT 1000® solar H1Z2Z2-K PV cables are designed to make connections between solar modules and between module sets, as well as to connect module sets to inverter. Thanks to high environmental resistance they are suitable for all kinds of photovoltaic systems, panels mounted on roofs of buildings and extended solar power plants. Cables are halogen-free and can be safely installed in buildings. Flame propagation on single cable according to EN 60332-1, IEC 60332-1. Cables conform norm EN 50618 and IEC 62930. Estimated operation time: min. 25 years. Cables classified according to PN-EN 50575 (CPR).

Cat. no.nxmm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
Conductor
resistance
at 20 °C [Ω/km]
Current-carrying
capacity
[A]
blackred
S68300S68300.051×45,5565,0955
S68301S68301.051×66763,3970
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read