BiTsensor®PE(St)CH B2ca

Halogen-free cable for RS 485 transmission

Industrial application Industrial application
Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
Data transmission Data transmission

Basic

  • Type: Data transmission and telecommunication cables
  • Operating voltage: 300 V
  • Voltage test: 2500V
  • Capacity: in pair: 42 nF/km

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • Minimum installation temperature: -20°C

Wave impedance: 120 Ω ±10%
Min. bending radius: 30mm

Cable construction

  • Conductor material: tinned copper wires
  • Core construction: Class 2 (according to EN 60228, IEC 60228)
  • Insulation type: PE
  • Screen: foil screen, braided screen, double screen
  • Core arrangement: paired/triple/quadruple cable
  • Sheath type: LSOH
  • Sheath color: green

Fire and functional properties

  • Halogen-free, Low smoke emission EN 61034
  • Fire classification: B2ca

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • Safety systems: BMS

Cable BiTsensor®PE(ST)CH B2ca is dedicated for EIA/RS-485 transmission. The cable has a low capacity, thus ensuring high transmission speed for long connections. Used in protocol-based networks BACnet MS/TP, Linknet, MODbus RTU, etc. Cables may be used in dry and damp rooms, and are suitable for fixed installations. Cables classified according to PN-EN 50575 (CPR).

Cat. no.Cable typenxmm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
Conductor colours
EB0250BiTsensor®PE(St)CH 1x2x0,22 mm² B2ca1x2x0,225,641white, blue
EB0251BiTsensor®PE(St)CH 2x2x0,22 mm² B2ca2x2x0,227,162Pair 1: white, blue
Pair 2: red, black
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read
What Internet Cables to Use? Types of Network Cables. 

What Internet Cables to Use? Types of Network Cables. 

Basic network cables forming the foundation....

Read