BiT 1000®CY

Flexible, screened, control and power supply cables, rated 0,6/1kV

Industrial application Industrial application
Indoor application Indoor application
Underground installation Underground installation
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
High flexibility High flexibility
Electromagnetic compatibility Electromagnetic compatibility

Basic

  • Type: Control and power cables
  • Operating voltage: 0,6/1 kV
  • Voltage test: 50Hz: 4000 V
  • Insulation resistance: 20 MΩ x km
  • Min. bending radius of movable connections: 12xØ
  • Min. bend radius of permanent connection: 6xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: PVC
  • Screen: braided screen
  • Core arrangement: single-core cable, multi-core cable
  • Sheath color: black

Flame retardant

  • For a single insulated cable

Installation conditions

  • Internal application
  • External application
  • Underground installation

Environmental resistance

  • UV resistance

BiT 1000®CY cables are designed for connections in control and signalling circuits, as power supply cables for mobile and portable devices in places exposed to vibrations. Insulation materials and construction of BIT 1000® CY cable enable easy and fast connections and ensure their high durability. They are suitable for fixed installations and for flexible connections in industrial devices, technological lines and machines operating in dry and damp rooms. Cables suitable for outdoor installation – outer sheath is UV resistant. Cables designed also for direct burial in ground. Properly connected screen ensures full electromagnetic compatibility (EMC).

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
S659002×0,59,6136
S659013G0,510148
S659024G0,510,6168
S659035G0,511,2190
S659046G0,512216
S659057G0,512220
S659068G0,513,1255
S6590710G0,514,9315
S6590812G0,514,9320
S6590914G0,515,4345
S6591016G0,516,3390
S6591118G0,517,1425
S6596119G0,517,1425
S6596220G0,517,8460
S6591221G0,517,8460
S6259125G0,520555
S6591330G0,520,6600
S6596337G0,522,2700
S625922×0,759,8150
S625933G0,7510,2166
S625944G0,7510,9190
S625955G0,7511,8220
S659156G0,7512,6245
S625967G0,7512,6250
S659168G0,7513,8290
S6591710G0,7515,7355
S6259712G0,7515,7370
S6591814G0,7516,5410
S6591916G0,7517,3450
S6259818G0,7518,1490
S6596419G0,7518,1495
S6596520G0,7519545
S6592021G0,7519550
S6259925G0,7521,2645
S626472×1,010,1162
S626483G1,010,8182
S626494G1,011,2210
S626425G1,012,2240
S659276G1,013,2275
S626437G1,013,2280
S659288G1,014,3320
S6263410G1,016,5405
S6264412G1,016,5420
S6592914G1,017,2460
S6593016G1,018505
S6264518G1,018,8555
S6596619G1,018,8560
S6596720G1,019,8610
S6593121G1,019,8615
S6264625G1,022,3750
S626352×1,511,1192
S626363G1,511,4215
S626374G1,512,4260
S626385G1,513,5295
S659416G1,514,4335
S626397G1,514,4345
S659428G1,515,6395
S6594310G1,518,2500
S6264012G1,518,2520
S626502×2,512,2234
S626513G2,512,9270
S626524G2,513,9317
S626535G2,515375
S626547G2,516,3454
S6265510G2,520,6622
S6265614G2,521,6813
S6265716G2,522,9914
S6265818G2,524,51008
S6265925G2,5291267
S626602×413,4289
S626613G414342
S626624G415,2408
S626635G416,5488
S626647G417,7618
S6266510G422,8865
S626663G615,3431
S626674G616,9541
S626685G618,1644
S626697G619,7798
S626703G1018,7687
S626714G1020,8832
S626725G1022,21004
S626737G1024,21256
S626743G1621,1933
S626754G1623,41142
S626765G1625,31389
S626777G1627,41790
S626783G2525,71423
S626794G2528,61790
S626805G2530,82159
S626813G3527,91855
S626824G3531,42316
S626835G3533,92795
S626843G50332532
S626854G5036,83164
S626865G5039,93861
S626873G7037,73393
S626884G70424245
S626895G7045,65164
S626903G9542,44439
S626914G9547,55578
S626925G9552,16807
S626933G12044,95330
S626944G12050,96730
S626954G15057,58509
S626964G18564,110495
S626974G24071,113153
single core cables
S626001×1,57,890
S626011×2,58,4110
S626021×410,1176
S626031×610,7210
S626041×1012291
S626051×1613,2387
S626061×2515453
S626071×3516550
S626081×5018,5748
S626091×7020,5976
S626101×95231268
S626111×12024,51536
S626121×15027,21875
S626131×18530,22242
S626141×24033,22883
S626151×30036,73618
S626161G1,57,890
S626171G2,58,4110
S626181G410,1176
S626191G610,7210
S626201G1012291
S626211G1613,2387
S626221G2515453
S626231G3516550
S626241G5018,5748
S626251G7020,5976
S626261G95231268
S626271G12024,51536
S626281G15027,21875
S626291G18530,22242
S626301G24033,22283
S626311G30036,73618
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read