YTKSY

Telecommunication station cable

Indoor application Indoor application

Basic

  • Type: Telecommunication and low-voltage cables
  • Min. bend radius of permanent connection: 10xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 70°C
  • Minimum installation temperature: -10°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Single-wire conductor
  • Insulation type: PVC
  • Core arrangement: paired/triple/quadruple cable
  • Sheath type: PVC
  • Sheath color: white

Flame retardant

  • For a single insulated cable

Installation conditions

  • Internal application

Cables designed for connections of telephone and tele-transmission devices. Cables classified according to EN 50575 (CPR).

Cat. non x 2 x mmOuter
diameter
[mm]
Approximate
cable weight
[kg/km]
TS00371x2x0,43,012,0
TS00382x2x0,43,816,0
TS00393x2x0,44,223,0
TS00405x2x0,44,832,0
TS00416x2x0,45,438,0
TS00427x2x0,45,443,0
TS004310x2x0,46,255,0
TS004412x2x0,46,663,0
TS004514x2x0,47,371,0
TS004621x2x0,48,6102,0
TS004728x2x0,49,6128,0
TS004830x2x0,410,9137,0
TS004935x2x0,411,8160,0
TS005042x2x0,415,0187,0
TS005148x2x0,416,0205,0
TS005253x2x0,416,5228,0
TS00021 x 2×0,53,015,0
TS00032 x 2×0,53,920,0
TS00053 x 2×0,54,229,0
TS00075 x 2×0,54,841,0
TS00086 x 2×0,55,451,0
TS00097 x 2×0,55,857,0
TS001110 x 2×0,56,476,0
TS001212 x 2×0,56,987,0
TS001314 x 2×0,57,498,0
TS001521 x 2×0,59,1144,0
TS001728 x 2×0,510,3188,0
TS001830 x 2×0,511,3196,0
TS001935 x 2×0,512,2227,0
TS002042x2x0,516,5266,0
TS002148x2x0,517,5295,0
TS002253x2x0,518,0324,0
TS00231x2x0,63,220,0
TS00242x2x0,64,130,0
TS00253x2x0,64,747,0
TS00265x2x0,65,469,0
TS00616x2x0,65,883,0
TS00627x2x0,66,294,0
TS006310x2x0,67,0131,0
TS006412x2x0,67,6152,0
TS006514x2x0,68,0174,0
TS006621x2x0,69,7248,0
TS00281x2x0,84,025,0
TS00292x2x0,85,438,0
TS00313x2x0,86,359,0
TS00325x2x0,87,587,0
TS00336x2x0,88,0104,0
TS00347x2x0,88,6118,0
TS003510x2x0,810,0164,0
TS005312x2x0,810,7191,0
TS005414x2x0,811,3218,0
TS003621x2x0,813,7310,0
TS005528x2x0,820,5408,0
TS005630x2x0,821,0434,0
TS005735x2x0,823,5495,0
TS005842x2x0,824,5602,0
TS005948x2x0,826,0674,0
TS006053x2x0,827,0740,0
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
Coaxial Cables. Impedance, Attenuation, Applications.

Coaxial Cables. Impedance, Attenuation, Applications.

A coaxial cable is a specialized type of…

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read