HTKSHekw

Halogen-free telecommunication cable

Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)

Basic

  • Type: Fire resistant cables
  • Voltage test: Napięcie przemienne 1500 V# Napięcie stałe 2250 V
  • Insulation resistance: min 200 MΩ/km
  • Capacity: 150 nF/km

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • Minimum installation temperature: -5°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 1 (according to EN 60228, IEC 60228)
  • Screen: foil screen
  • Core arrangement: paired/triple/quadruple cable
  • Sheath color: red

Fire and functional properties

  • Halogen-free

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application

Certificates

  • CNBOP

Halogen-free special cables for interconnecting station equipment, telephone and teletransmission equipment and data transmission devices by means of analogue and digital signals in control and signalling fire protections systems. The cables are used primarily as transmission and power suplly lines for line equipment (sensors, linear modules) in supervised lines of fire signalling systems and autonomous fire extinguisher and smoke removal control systems. The cables are incorporated in systems used at the „0″ moment of fire origination (the moment of fire detection by the central detector). The cables can be used for transmitting trigger signals or conditions to auxiliary devices, which are activated by the central fire signalling mechanism upon detection of a fire (e.g. disconnection of a residential ventilation system, downward movement of passenger lifts, switching off of the power supply of building). Static screen protects the cable against interferences of external magnetic fields.

Cat.no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
TN03461x2x0,53,616
TN03471x4x0,5422
TN03482x2x0,54,724
TN03493x2x0,55,130
TN03504x2x0,55,737
TN03515x2x0,56,243
TN03527x2x0,56,958
TN035310x2x0,57,976
TN035412x2x0,58,587
TN035514x2x0,59,199
TN03001x2x0,84,626
TN03011x4x0,85,240
TN03022x2x0,86,344
TN03033x2x0,87,161
TN03044x2x0,8877
TN03055x2x0,88,792
TN03127x2x0,89,8124
TN030910x2x0,811,5173
TN035612x2x0,812,4201
TN035714x2x0,813,3230
TN035821x2x0,814,5327
TN035930x2x0,816,7445
TN036042x2x0,819,6620
TN03061x2x1,05,637
TN03131x4x1,06,461
TN03072x2x1,07,767
TN03113x2x1,08,793
TN03144x2x1,09,9117
TN03155x2x1,010,8145
TN03167x2x1,012,1189
TN031710x2x1,014,2263
TN036112x2x1,015,4307
TN036214x2x1,016,6352

 

Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read
Fiber Optic Cables – efficient methods of data transmission

Fiber Optic Cables – efficient methods of data transmission

Fiber optic cables, which gained popularity at the…

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read