HTKSHekw FE180/PH120/E90

Fire resistant, halogen-free telecommunication cable

Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
180 min. insulation resistance to fire (IEC 60331) 180 min. insulation resistance to fire (IEC 60331)
90 min. circuit integrity (VDE 4102-12) 90 min. circuit integrity (VDE 4102-12)
Sprinkler zones Sprinkler zones
120 min. circuit integrity (EN 50200) 120 min. circuit integrity (EN 50200)

Basic

  • Type: Fire resistant cables
  • Operating voltage: 225 V
  • Voltage test: AC: 1500 V; DC: 2250 V
  • Insulation resistance: 500 MΩxkm
  • Inductance: Mutual capacitance of pair at 1 kHz (maximum): 150 nF/km
  • Min. bend radius of permanent connection: 10xØ

Operating temperature

  • fixed installation from: -30°C
  • fixed installation up to: 80°C
  • Minimum installation temperature: -5°C

Pair loop resistance at 20 °C (maximum):
0,8 mm – 75 Ω/km
1,0 mm – 48 Ω/km
1,4 mm – 26,6 Ω/km
1,8 mm – 14,96 Ω/km
2,3 mm – 9,6 Ω/km
2,8 mm – 6,4 Ω/km

Cable construction

  • Conductor material: copper wires
  • Core construction: Single-wire conductor
  • Insulation type: LSOH
  • Screen: foil screen
  • Core arrangement: paired/triple/quadruple cable
  • Sheath type: LSOH
  • Sheath color: red

Fire and functional properties

  • Fire resistant (IEC 60331), For use in sprinklers zone, Low smoke emission EN 61034, Fire integrity function (EN 50200, DIN 4102-12), Halogen-free

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application

Certificates

  • CNBOP

Fire resistant, halogen-free telecommunication cables designed for emergency lighting installations, alarm- , signalling-, and teletransmission systems, in sound alarm systems as well as in fire warning systems, fire automation and other safety ensuring installations. Static screen (ekw) protects the cable against interferences of external magnetic fields. Under fire conditions those cables ensure proper operation of installations for at least 120 minutes (PH120) and durability of conductors insulation for 180 minutes (FE180). During burning cables do not emit corrosive gases or dense smoke. Cables are suitable for fixed installations inside buildings. HTKSHekw FE180/PH90 (E90) cables have been tested in accordance with the requirements of DIN 4102 p.12 and can be installed in E90 cable support systems as their elements (installation on clamps located every 30cm and 60cm).

Nr kat.n x mmOuter
diameter
[mm]
Approximate
cable weight
[kg/km]
B101701x2x0,86,548
B101801x4x0,87,368
B101742x2x0,88,785
B101773x2x0,89,495
B101784x2x0,810,7118
B101815x2x0,811,6146
B101827x2x0,812,7174
B101838x2x0,813,3193
B1018410x2x0,814,7231
B101711x2x1,07,159
B101851x4x1,0885
B101752x2x1,09,6106
B101863x2x1,010,4122
B101874x2x1,011,9152
B101795x2x1,013190
B101897x2x1,014,3231
B101908x2x1,014,9256
B1019110x2x1,016,6309
B101721x2x1,48,282
B101921x4x1,49,3126
B101762x2x1,411,4159
B101933x2x1,412,4183
B101944x2x1,414,3233
B101955x2x1,415,6296
B101967x2x1,417,2365
B101978x2x1,418,4425
B1019810x2x1,420,5515
B101731x2x1,89,7119
B101991x4x1,811,1188
B102002x2x1,813,6238
B102013x2x1,814,9276
B102024x2x1,817,1351
B102035x2x1,819,1465
B102047x2x1,821575
B102058x2x1,822642
B1020610x2x1,825805
B102071x2x2,311161
B102081x4x2,312,5264
B102092x2x2,315,5327
B102103x2x2,317388
B102114x2x2,320,1518
B102125x2x2,322660
B102137x2x2,324,7851
B102148x2x2,325,8953
B1021510x2x2,329,21193
B102161x2x2,812,2211
B102171x4x2,814357
B102182x2x2,817,4435
B102193x2x2,819,6546
B102204x2x2,822,7704
B1022110x2x2,833,11286
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read
How to Select a Servo Cable for a Motor? The most important aspects

How to Select a Servo Cable for a Motor? The most important aspects

Frequency converters play a crucial role in various...

Read
What Internet Cables to Use? Types of Network Cables. 

What Internet Cables to Use? Types of Network Cables. 

Basic network cables forming the foundation....

Read