Basic

  • Type: Intrinsically safe control cables
  • Operating voltage: 300/500 V
  • Voltage test: 50Hz: 3000V
  • Insulation resistance: 20 MΩ x km
  • Inductance: max: 0,6 mH/km
  • Min. bending radius of movable connections: 7,5xØ
  • Min. bend radius of permanent connection: 4xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: PVC
  • Core arrangement: multi-core cable
  • Sheath type: PVC
  • Sheath color: blue

Fire and functional properties

  • oxygen index >29

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • External application
  • Flexible connections

Environmental resistance

  • Oil resistant EN 60811-404
  • UV resistance
  • Hydrocarbon resistant
  • O3 – wysoka olejoodporność

Flexible power/control cables designed for operation in intrinsically safe circuits. They are suitable for fixed installations and for flexible connections in industrial devices, technological lines and machines operating in dry and damp rooms. High flexibility of IB-BIT 500® cable enables easy and fast connections and ensures their high durability. Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
S551002×0,5536
S551013×0,55,344
S551024×0,55,852
S551035×0,56,362
S551047×0,5778
S551058×0,57,792
S5514010×0,59,4126
S5510612×0,59,4135
S5514114×0,59,8150
S5514216×0,510,4170
S5510718×0,510,9185
S5514319×0,510,9190
S5514421×0,511,6215
S5514525×0,513,1255
S5514627×0,513,1265
S5510930×0,513,8290
S5514734×0,514,8335
S5511037×0,514,8345
S5514840×0,515,3370
S5514950×0,517,6475
S5515061×0,518,9560
S551112×0,755,445
S551123×0,755,754
S551134×0,756,364
S551145×0,75780
S551516×0,757,694
S551157×0,757,6100
S551168×0,758,4116
S5515210×0,7510,2158
S5511712×0,7510,2168
S5515314×0,7510,7190
S5515416×0,7511,5220
S5511818×0,7512,1245
S5515519×0,7512,1250
S5515621×0,7512,7275
S5515725×0,7514,5335
S5515827×0,7514,5345
S5515930×0,7515375
S5516034×0,7516,6450
S5516137×0,7516,6465
S5516240×0,7517,2500
S5516350×0,7519,5625
S551202×1,05,752
S551213×1,06,164
S551224×1,06,880
S551235×1,07,496
S551646×1,08112
S551247×1,08118
S551258×1,09,3148
S5516510×1,010,9188
S5512612×1,010,9204
S5516614×1,011,6235
S5516716×1,012,2264
S5512718×1,012,8294
S5516819×1,012,8300
S5516921×1,013,7336
S5517025×1,015,5405
S5517130×1,016,4470
S551292×1,56,771
S551303×1,57,187
S551314×1,57,8110
S551325×1,58,5130
S551726×1,59,6162
S551337×1,59,6172
S551738×1,510,6202
S5517410×1,512,7265
S5513412×1,512,7285
S5517514×1,513,5325
S5517616×1,514,3370
S5517719×1,515420
S5517821×1,516,2475
S5517925×1,518,5580
S551802×2,57,8102
S551353×2,58,3126
S551364×2,59,5166
S551375×2,510,4200
S551386×2,511,5240
S551397×2,511,5260
S5518110×2,515,2390
S5518212×2,515,2425
S5518314×2,516,4495
S5518416×2,517,3560
S595202x2x0,57,363
S595213x2x0,58,272
S595224x2x0,59,397
S595235x2x0,510122
S595246x2x0,510,4130
S595257x2x0,511,8156
S595268x2x0,512,3172
S5952710x2x0,513,2205
S5952812x2x0,514,3245
S5952914x2x0,515,1275
S5953016x2x0,516,6335
S5953118x2x0,517,3360
S5953220x2x0,517,8390
S5953324x2x0,518,5455
S595342x2x0,75880
S595353x2x0,759,498
S595364x2x0,7510,1122
S595375x2x0,7510,9152
S595386x2x0,7511,5170
S595397x2x0,7512,9196
S595408x2x0,7513,7225
S5954110x2x0,7514,6270
S5954212x2x0,7516325
S5954314x2x0,7517370
S5954416x2x0,7518,4435
S5954518x2x0,7519,1470
S5954620x2x0,7519,7510
S5954724x2x0,7520,3590
S595482x2x1,08,592
S595493x2x1,09,9116
S595504x2x1,010,8142
S595515x2x1,011,8184
S595526x2x1,012,2202
S595537x2x1,013,9240
S595548x2x1,014,5270
S5955510x2x1,015,6320
S5955612x2x1,017390
S5955714x2x1,018,3450
S5955816x2x1,019,5515
S595592x2x1,510,1132
S595603x2x1,511,6160
S595614x2x1,512,6198
S595625x2x1,513,8258
S595636x2x1,514,3280
S595647x2x1,516,4340
S595658x2x1,517,2380
S5956610x2x1,518,6465
S5956712x2x1,519,9540
S5956814x2x1,521,1620
S595692x2x2,512,1192
S595703x2x2,513,8235
S595714x2x2,515,1295
S595725x2x2,516,7385
S595736x2x2,517,3425
S595747x2x2,519,6500
S595758x2x2,520,5560
S5957610x2x2,522,3690
S5957712x2x2,523,8805
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read
How to Select a Servo Cable for a Motor? The most important aspects

How to Select a Servo Cable for a Motor? The most important aspects

Frequency converters play a crucial role in various...

Read