BiTLAN®F/UTPf cat.5e outdoor 200 MHz

Data transmission cable, screened and suitable for external applications

Outdoor application Outdoor application
UV resistance UV resistance
Data transmission Data transmission

Basic

  • Type: LAN cables
  • Operating voltage: 150 V
  • Voltage test: AC 50 Hz: 700 V # DC: 1000 V
  • Insulation resistance: 5 GΩ x km
  • Capacity: at 1 kHz (max): 50 ± 5 nF/km

Operating temperature

  • fixed installation from: -30°C
  • fixed installation up to: 80°C
  • Minimum installation temperature: -10°C

DC loop resistance at 20 °C (max): 190 Ω/km
Resistance unbalance within a pair: ≤ 2 %
Capacitance unbalance pair to ground at 1kHz (max):
1600 pF/km
Characteristic impedance at 100 MHz: 100 ± 5 Ω

Cable construction

  • Conductor material: copper wires
  • Core construction: Single-wire conductor
  • Insulation type: PE
  • Screen: foil screen
  • Core arrangement: paired/triple/quadruple cable
  • Sheath type: PE
  • Sheath color: black

Installation conditions

  • External application
  • Underground installation

Environmental resistance

  • Water resistance
  • UV resistance

BiTLAN F/UTPs cat. 5e outdoor 200MHz cables are applicable to computer networks with operating frequency band up to 200 MHz. Suitable for transmission of data, audio and video signals, with bitrate up to 1 Gb/s. Dedicated for fixed installations within outdoor structured cabling systems as per EN 50173-1, ISO/IEC 11801, ANSI/TIA 568-C.2 standards. Additional collective Al/Cop screen with CuSn drain wire acts as a protection against external electromagnetic interferences and as a moisture barrier. Cables are filled hydrophobic gel to prevent waterpenetration with UV resistant outer sheath allowing installation external application and direct burial. Cables classified according to EN 50575 (CPR).

Cat. no.ConstructionCu wireOuter diameterApproximate
cable weight
[kg/km]
Bandwidth
[MHz]
TI0013F/UTPf cat.5e outdoor24AWG(0,5)7,453200
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
What Internet Cables to Use? Types of Network Cables. 

What Internet Cables to Use? Types of Network Cables. 

Basic network cables forming the foundation....

Read
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read