BiT RE-2Y(St)HSWAH, 500V

Steel wire armoured halogen-free instrumentation cables with collective electrostatic screen, rated 500 V

Industrial application Industrial application
Indoor application Indoor application
Underground installation Underground installation
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
Data transmission Data transmission

Basic

  • Type: Instrumentation cables
  • Operating voltage: 500 V
  • Voltage test: Core/core: 2000 V # Core/screen: 2000 V
  • Insulation resistance: > 5 GΩ x km
  • Min. bend radius of permanent connection: 10xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 2 (according to EN 60228, IEC 60228)
  • Insulation type: PE
  • Screen: foil screen
  • Core arrangement: paired/triple/quadruple cable
  • Sheath type: LSOH
  • Sheath color: black

Fire and functional properties

  • Halogen-free, Low smoke emission EN 61034

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • External application
  • Underground installation

Environmental resistance

  • Increased mechanical resistance
  • UV resistance

Additional elements

  • Steel wire braid reinforcement

Cables designed for data transmission in numerical control systems ensuring optimum transmission of data up to 200 Kbit/s. Collective electrostatic screen protects against external interferences. Cables are suitable for application indoor and outdoor, in dry and damp rooms and also for direct burial as well as in conduits in places that are subject to mechanical stresses mainly from tensile forces. Outer sheath is UV resistant. Cables classified according to EN 50575 (CPR).

Cat.no.
(paired cables)
n x 2 x mm2Inner
diameter
[mm]
Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
ID64201x2x0,56,110,7267
ID64212x2x0,59,514,1408
ID64224x2x0,510,915,7486
ID64235x2x0,512,217555
ID64246x2x0,51317,8594
ID64258x2x0,514,319,1671
ID642610x2x0,516,221,2787
ID642712x2x0,516,821,8840
ID642816x2x0,51924981
ID642920x2x0,521,226,41243
ID643024x2x0,523,4291398
ID64311x2x0,756,611,2290
ID64322x2x0,7510,315,1461
ID64334x2x0,7512,217558
ID64345x2x0,7513,318,1627
ID64356x2x0,7514,319,1676
ID64368x2x0,7515,920,9794
ID643710x2x0,7517,822,8905
ID643812x2x0,7518,523,5973
ID643916x2x0,7521,126,71278
ID644020x2x0,7523,629,21475
ID644124x2x0,752632,21802
ID64421x2x1,07,111,7315
ID64432x2x1,010,915,7493
ID64444x2x1,012,817,6604
ID64455x2x1,014,118,9683
ID64466x2x1,015,119,9737
ID64478x2x1,016,821,8870
ID644810x2x1,018,823,8996
ID644912x2x1,019,724,71093
ID645016x2x1,022,327,91417
ID645120x2x1,024,930,71660
ID645224x2x1,027,733,92028
ID64531x2x1,37,412333
ID64542x2x1,311,616,4539
ID64554x2x1,313,418,2657
ID64565x2x1,31520771
ID64576x2x1,31621836
ID64588x2x1,317,822,8977
ID645910x2x1,319,925,51233
ID646012x2x1,320,926,51353
ID646116x2x1,323,829,61627
ID646220x2x1,326,532,92036
ID646324x2x1,329,435,82324
ID64641x2x1,57,712,3345
ID64652x2x1,512,116,9564
ID64664x2x1,514,319,3713
ID64675x2x1,515,720,7810
ID64686x2x1,516,821,8878
ID64698x2x1,518,723,91042
ID647010x2x1,521,126,71316
ID647112x2x1,521,927,71441
ID647216x2x1,525,130,91733
ID647320x2x1,527,934,32167
ID647424x2x1,530,937,72599

 

Cat.no.
(triple cables)
n x 3 x mm2Inner
diameter
[mm]
Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
ID64751x3x0,56,411278
ID64762x3x0,511,115,9496
ID64774x3x0,513,218588
ID64785x3x0,514,519,3662
ID64796x3x0,515,920,7739
ID64808x3x0,51823860
ID648110x3x0,520,625,6999
ID648212x3x0,521,326,71169
ID648316x3x0,524,229,81402
ID648420x3x0,526,732,71749
ID648524x3x0,53036,62138
ID64861x3x0,757,211,8314
ID64872x3x0,7512,217554
ID64884x3x0,7514,519,3670
ID64895x3x0,751620,8758
ID64906x3x0,7517,722,7877
ID64918x3x0,7519,824,8996
ID649210x3x0,7522,928,31287
ID649312x3x0,7523,729,31396
ID649416x3x0,7526,932,91800
ID649520x3x0,7529,736,32233
ID649624x3x0,7533,540,12546
ID64971x3x1,07,512,1333
ID64982x3x1,013,117,9611
ID64994x3x1,015,320,1731
ID65005x3x1,016,821,8842
ID65016x3x1,018,723,7965
ID65028x3x1,020,925,91103
ID650310x3x1,024,229,81438
ID650412x3x1,02530,61551
ID650516x3x1,028,534,72023
ID650620x3x1,031,638,22515
ID65081x3x1,37,812,4356
ID65092x3x1,313,718,5660
ID65104x3x1,316,321,3829
ID65115x3x1,317,922,9946
ID65126x3x1,319,824,81086
ID65138x3x1,322,227,81368
ID651410x3x1,325,731,91760
ID651512x3x1,326,632,81903
ID651616x3x1,330,2372459
ID651720x3x1,333,640,42929
ID65191x3x1,58,112,7370
ID65202x3x1,514,419,2693
ID65214x3x1,517,122,1871
ID65225x3x1,518,823,8996
ID65236x3x1,520,8261158
ID65248x3x1,523,529,11461
ID652510x3x1,52733,21857
ID652612x3x1,528,134,32031
ID652716x3x1,531,938,72623
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
Fiber Optic Cables – efficient methods of data transmission

Fiber Optic Cables – efficient methods of data transmission

Fiber optic cables, which gained popularity at the…

Read
What Internet Cables to Use? Types of Network Cables. 

What Internet Cables to Use? Types of Network Cables. 

Basic network cables forming the foundation....

Read