Basic
- Type: Intrinsically safe control cables
- Operating voltage: 0,6/1 kV
- Insulation resistance: 20 MΩ x km
- Capacity: 0,7 mH/k
- Min. bending radius of movable connections: 12xØ
- Min. bend radius of permanent connection: 6xØ
Flexible, screened control cables with number coded conductors for intrinsically safe circuits, rated 0,6/1 kV
Industrial application
Indoor application
Underground installation
Outdoor application
UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Oxygen index
High flexibility
Electromagnetic compatibility
Oil resistance (EN 60811-404)
Hydrocarbon resistantFlexible power/control cables designed for operation intrinsically safe circuits. They are suitable for installations outdoor and indoor in dry and damp rooms. Common screen of tinned copper wire braid ensures very good protection against external electromagnetic field. Reciprocal connection of screen to earth ensures full electromagnetic compatibility (EMC). Design and high flexibility of IB-BiT 1000®CY cable simplifies installation and compounds used enable easy and fast connections and ensure their high durability. Cables designed also for direct burial in ground. Classified according to EN 50575 (CPR).
| Cat. no. | n x mm2 | Outer diameter [mm] | Approximate cable weight [kg/km] |
| IB0700 | 2×0,5 | 9,6 | 136 |
| IB2001 | 3×0,5 | 10 | 148 |
| IB2002 | 4×0,5 | 10,6 | 168 |
| IB2003 | 5×0,5 | 11,3 | 190 |
| IB2004 | 6×0,5 | 12 | 216 |
| IB2005 | 7×0,5 | 12 | 220 |
| IB2006 | 8×0,5 | 13,1 | 255 |
| IB2007 | 10×0,5 | 14,9 | 315 |
| IB2008 | 12×0,5 | 14,9 | 320 |
| IB2009 | 14×0,5 | 15,5 | 345 |
| IB2010 | 16×0,5 | 16,4 | 390 |
| IB2011 | 18×0,5 | 17,1 | 425 |
| IB2012 | 19×0,5 | 17,1 | 425 |
| IB2013 | 20×0,5 | 17,8 | 460 |
| IB2014 | 21×0,5 | 17,8 | 460 |
| IB2016 | 25×0,5 | 20 | 555 |
| IB2018 | 30×0,5 | 20,6 | 600 |
| IB2021 | 37×0,5 | 22,2 | 700 |
| IB0716 | 2×0,75 | 10 | 150 |
| IB2022 | 3×0,75 | 10,4 | 166 |
| IB2023 | 4×0,75 | 11,1 | 190 |
| IB2024 | 5×0,75 | 11,8 | 220 |
| IB2025 | 6×0,75 | 12,6 | 245 |
| IB2026 | 7×0,75 | 12,6 | 250 |
| IB2027 | 8×0,75 | 13,8 | 290 |
| IB2028 | 10×0,75 | 15,7 | 355 |
| IB2029 | 12×0,75 | 15,7 | 370 |
| IB2030 | 14×0,75 | 16,6 | 410 |
| IB2031 | 16×0,75 | 17,3 | 450 |
| IB2032 | 18×0,75 | 18,1 | 490 |
| IB2033 | 19×0,75 | 18,1 | 495 |
| IB2034 | 20×0,75 | 19,1 | 545 |
| IB2035 | 21×0,75 | 19,1 | 550 |
| IB2037 | 25×0,75 | 21,2 | 645 |
| IB0736 | 2×1,0 | 10,3 | 162 |
| IB0838 | 3×1,0 | 10,8 | 182 |
| IB0836 | 4×1,0 | 11,5 | 210 |
| IB2051 | 5×1,0 | 12,2 | 240 |
| IB0837 | 6×1,0 | 13,2 | 275 |
| IB2052 | 7×1,0 | 13,2 | 280 |
| IB2053 | 8×1,0 | 14,3 | 320 |
| IB2054 | 10×1,0 | 16,6 | 405 |
| IB2055 | 12×1,0 | 16,6 | 420 |
| IB2056 | 14×1,0 | 17,2 | 460 |
| IB2057 | 16×1,0 | 18 | 505 |
| IB2058 | 18×1,0 | 18,8 | 555 |
| IB2059 | 19×1,0 | 18,8 | 560 |
| IB2060 | 20×1,0 | 19,9 | 610 |
| IB2061 | 21×1,0 | 19,9 | 615 |
| IB2063 | 25×1,0 | 22,4 | 750 |
| IB0756 | 2×1,5 | 11,1 | 192 |
| IB0841 | 3×1,5 | 11,6 | 215 |
| IB0840 | 4×1,5 | 12,7 | 260 |
| IB2074 | 5×1,5 | 13,5 | 295 |
| IB2075 | 6×1,5 | 14,4 | 335 |
| IB2076 | 7×1,5 | 14,4 | 345 |
| IB2077 | 8×1,5 | 15,7 | 395 |
| IB2078 | 10×1,5 | 18,2 | 500 |
| IB0842 | 12×1,5 | 18,2 | 520 |
| IB0776 | 2×2,5 | 12,1 | 234 |
| IB2097 | 3×2,5 | 12,6 | 270 |
| IB2098 | 4×2,5 | 13,6 | 317 |
| IB2099 | 5×2,5 | 14,8 | 375 |
| IB2101 | 7×2,5 | 15,9 | 454 |
| IB2103 | 10×2,5 | 19,8 | 622 |
| IB2105 | 14×2,5 | 21,6 | 813 |
| IB2106 | 16×2,5 | 22,9 | 914 |
| IB2107 | 18×2,5 | 23,8 | 1008 |
| IB2112 | 25×2,5 | 28,3 | 1267 |
Guidelines for laying electric cables in the ground
Read
Safety is a top priority for all of…
Read
Fiber optic cables are essential for transmitting data…
Read