BiTmining®NSSHCOEU 0,6/1 kV

Heavy duty, screened rubber cable for frequency converters, acc. to DIN VDE 0250-812

Industrial application Industrial application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
High flexibility High flexibility
Mechanical resistance Mechanical resistance
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Mining applications Mining applications

Basic

  • Type: Crane cables, Mining cables
  • Operating voltage: 0,6/1 kV
  • Min. bending radius of movable connections: 5xØ
  • Min. bend radius of permanent connection: 4xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -30°C
  • flexible connections up to: 80°C

Max. permissible conductor temp.: 90 °C
Max. short-circuit temp. at conductor: 200 °C

Max. tensile load on conductor: 15 N/mm²

Cable construction

  • Conductor material: tinned copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: rubber
  • Screen: braided screen
  • Core arrangement: multi-core cable
  • Sheath type: rubber
  • Sheath color: yellow

Flame retardant

  • For a single insulated cable

Installation conditions

  • Mining applications
  • Tunneling applications
  • Internal application
  • External application
  • Flexible connections

Environmental resistance

  • O3 – wysoka olejoodporność
  • Oil resistant EN 60811-404
  • Increased mechanical resistance
  • UV resistance

Motor power supply cables for frequency converter controlled drives on mobile equipment and machines under very high mechanical loads in dry and damp areas, outdoors and in explosion hazard areas. They meet the requirements of DIN EN 50628: Erection of electrical installations in underground mines, DIN VDE 0168: Erection of electrical installation in open-cast mines, quarries and similar works and DIN VDE 0298-3: Application of cables and cords in power installations – Guide to use of non-harmonized low voltage cables.

Cat. no.n x mm2Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
IP42003×16+3×2,525-281329
IP42013×25+3×430-331961
IP42023×35+3×632-352336
IP42093×35+3×16/332-352336
IP42033×50+3×25/339-423226
IP42043×70+3×35/344-474383
IP42103×95+3×35/348-515469
IP42053×95+3×50/349-525322
IP42063×120+3×70/354-576935
IP42073×150+3×70/359-628346
IP42083×185+3×95/366-6910253
Fiber Optic Cables – efficient methods of data transmission

Fiber Optic Cables – efficient methods of data transmission

Fiber optic cables, which gained popularity at the…

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read