BiTLAN®U/FTP cat.6 LSOH 350 MHz

Halogen-free, data transmission cable, screened

Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
Data transmission Data transmission

Basic

  • Type: LAN cables
  • Operating voltage: 150 V
  • Voltage test: AC 50 Hz: 700 V # DC: 1000 V
  • Insulation resistance: 2 GΩ x km
  • Capacity: at 1 kHz: 45 ± 5 nF/km

Operating temperature

  • fixed installation from: -30°C
  • fixed installation up to: 70°C
  • Minimum installation temperature: -10°C

DC loop resistance at 20 °C (max): 145 Ω/km
Resistance unbalance within a pair: ≤ 2 %
Capacitance unbalance pair to ground at 1 kHz (max): 1600 pF/km
Characteristic impedance at 100 MHz: 100 ± 5 Ω

Cable construction

  • Conductor material: copper wires
  • Core construction: Single-wire conductor
  • Insulation type: PE
  • Screen: foil screen
  • Core arrangement: paired/triple/quadruple cable
  • Sheath type: LSOH
  • Sheath color: orange

Fire and functional properties

  • Halogen-free, Low smoke emission EN 61034

Flame retardant

  • For a single insulated cable

Installation conditions

  • Internal application

BiTLAN U/FTP cat.6 350MHz LSOH cables are applicable to computer networks with operating frequency band up to 350MHz. Suitable for transmission of data, audio and video signals, with bitrate up to 1Gb/s. Additional individual Al/Pet screen with tinned copper drain wire acts as a protection against external electromagnetic interferences. Dedicated for fixed installations within indoor structured cabling systems as per EN 50173-1, ISO/IEC 11801, ANSI/TIA 568-C.2 standards, as well as within industrial networks exposed to external electromagnetic interferences. Cables with flame retardant LSOH outer sheath ensuring low smoke emission acc. to EN 50268, IEC 61034-1(2) and limited emission of corrosive gases acc. to EN 50267, IEC 60754-2, should be installed in places with increased fire safety requirements. Cables classified according to EN 50575 (CPR).

Cat. no.ConstructionCu wireOuter diameter
[mm]
Approximate
cable weight
[kg/km]
Bandwidth
[MHz]
TI0083U/FTP cat.6 LSOH23AWG7,150350
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
What Internet Cables to Use? Types of Network Cables. 