BiTmining®(N)TMCGCWOEU

Medium voltage, screened single core cable based on DIN VDE 0250-813

Industrial application Industrial application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Oxygen index Oxygen index
High flexibility High flexibility
Mechanical resistance Mechanical resistance
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Open-pit mining Open-pit mining

Basic

  • Type: Mining cables
  • Min. bending radius of movable connections: ≥ 10xØ
  • Min. bend radius of permanent connection: ≥ 6xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -25°C
  • flexible connections up to: 80°C

Max. permissible conductor temp.: 90 °C
Max. short-circuit temp. at conductor: 200 °C
Max. tensile load per conductor: 15 N/mm²

Cable construction

  • Conductor material: tinned copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: rubber
  • Sheath type: rubber
  • Sheath color: red

Fire and functional properties

  • oxygen index >29

Flame retardant

  • For a single insulated cable

Installation conditions

  • Mining applications
  • Internal application
  • External application
  • Flexible connections

Environmental resistance

  • UV resistance
  • Oil resistant EN 60811-404

Flexible high voltage cable used in short lengths, e.g. as a connection in switch-gear or transformer houses where small bending radius is requested.

BiTmining®(N)TMCGCWOEU 6/10 kV
n x mm2Maximum
conductor
resistance
[Ω/km]
Nominal
diameter
over
insulation
[mm]
Outer
diameter
min.-max.
[mm]
Calculated
cable weight
[kg/km]
Current carrying
capacity
[A]
BM17001×25/160.79513.020-23760135
BM17011×35/160.56514.021-24855169
BM17021×50/160.39316.022-251010207
BM17031×70/160.27717.025-281280268
BM17041×95/160.21019.026-291515328
BM10201×120/160.16420.028-311765383
BM17061×150/250.13222.031-342230444
BM17071×185/250.10825.033-362590510
BM17081×240/250.081726.035-383125607
BM17091×300/250.065429.038-413820703
BM17101×400/350.049533.042-454890823
BM17111×500/350.039135.045-585890946
BiTmining®(N)TMCGCWOEU 8,7/15 kV
n x mm2Maximum
conductor
resistance
[Ω/km]
Nominal
diameter
over
insulation
[mm]
Outer
diameter
min.-max.
[mm]
Calculated
cable weight
[kg/km]
Current carrying
capacity
[A]
BM17201×25/160.79513.020-23760135
BM17211×35/160.56514.021-24855169
BM17221×50/160.39316.022-251010207
BM17231×70/160.27717.025-281280268
BM17241×95/160.21019.026-291515328
BM17251×120/160.16420.028-311765383
BM17261×150/250.13222.031-342230444
BM17271×185/250.10825.033-362590510
BM17281×240/250.081726.035-383125607
BM17291×300/250.065429.038-413820703
BM17301×400/350.049533.042-454890823
BM17311×500/350.039135.045-585890946
BiTmining®(N)TMCGCWOEU 12/20 kV
n x mm2Maximum
conductor
resistance
[Ω/km]
Nominal
diameter
over
insulation
[mm]
Outer
diameter
min.-max.
[mm]
Calculated
cable weight
[kg/km]
Current carrying
capacity
[A]
BM17361×25/160.79516.023-26890135
BM10271×35/160.56517.025-281030169
BM17371×50/160.39319.026-291215207
BM17381×70/160.27721.028-311450268
BM10261×95/160.21022.maj31-331770328
BM17391×120/160.16424.032-352040383
BM10251×150/250.13226.034-372445444
BM10401×185/250.10828.037-402900510
BM08611×240/250.081730.039-413450607
BM17411×300/250.065432.041-444057703
BM17421×400/350.049536.046-495165823
BM17431×500/350.039139.049-526305946
BiTmining®(N)TMCGCWOEU 14/25 kV
n x mm2Maximum
conductor
resistance
[Ω/km]
Nominal
diameter
over
insulation
[mm]
Outer
diameter
min.-max.
[mm]
Calculated
cable weight
[kg/km]
Current carrying
capacity
[A]
BM17501×25/160.79518.025-28980135
BM17511×35/160.56519.025-281100169
BM17521×50/160.39320.026-291265207
BM17531×70/160.27722.028-311580268
BM17541×95/160.21024.031-331850328
BM17551×120/160.16425.032-352125383
BM17561×150/250.13227.034-372610444
BM17571×185/250.10829.037-402990510
BM17581×240/250.081731.039-413530607
BM17591×300/250.065433.041-444170703
BM17601×400/350.049537.046-495390823
BM17611×500/350.039140.049-526430946
BiTmining®(N)TMCGCWOEU 18/30 kV
n x mm2Maximum
conductor
resistance
[Ω/km]
Nominal
diameter
over
insulation
[mm]
Outer
diameter
min.-max.
[mm]
Calculated
cable weight
[kg/km]
Current carrying
capacity
[A]
BM17701×25/160.79520.027-301100135
BM17711×35/160.56521.028-311210169
BM17721×50/160.39323.031-341475207
BM17731×70/160.27724.033-361740268
BM17741×95/160.21026.034-372025328
BM17751×120/160.16427.037-402375383
BM17761×150/250.13228.maj39-422780444
BM17771×185/250.10832.041-443165510
BM17781×240/250.081733.042-453720607
BM17791×300/250.065436.045-484380703
BM17801×400/350.049540.050-535640823
BM17811×500/350.039142.053-566660946
What Internet Cables to Use? Types of Network Cables. 

What Internet Cables to Use? Types of Network Cables. 

Basic network cables forming the foundation....

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read
Fiber Optic Cables – Types and Symbol Meanings. Key aspects 

Fiber Optic Cables – Types and Symbol Meanings. Key aspects 

Fiber optic cables are essential for transmitting data…

Read