Basic
- Type: Crane cables
- Operating voltage: 0,6/1 kV
Screened, flexible, flat rubber cables for festoon systems, based on DIN VDE 0250-809
Industrial application
Indoor application
Outdoor application
UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2)
Electromagnetic compatibility
Oil resistance (EN 60811-404)
Festoon applicationMax. permissible conductor temp.: 90 °C
Max. short-circuit temp. at conductor: 250 °C
Max. tensile load on conductor: 15 N/mm²
Trolley travel speed: up to 180 m/min
Flexible, flat rubber cables designed for festoon applications, especially for hoisting gears transportation systems as well as for machine tools at medium mechanical stresses and for strong bends in one plane. Cables are suitable for both indoor and outdoor applications where resistance to oils, fats and chemicals is required.
| Cat. no. | n x mm2 | Nom. outer dimensions [mm] | Approximate cable weight [kg/km] |
| IP5330 | 4x2x1 | 11 x 33 | 640 |
| IP5331 | 7x2x1 | 12 x 56 | 1 114 |
| IP5332 | 12x2x1 | 12 x 88 | 1 788 |
| IP5333 | 4x4x1,5 | 15 x 41 | 1 100 |
| IP5334 | 5×1,5 | 8 x 25 | 368 |
| IP5335 | 8×1,5 | 8 x 38 | 562 |
| IP5336 | 12×1,5 | 8 x 56 | 829 |
| IP5337 | 6×2,5 | 8 x 33 | 615 |
| IP5338 | 12×2,5 | 8 x 63 | 1199 |
| IP5339 | 4×1,5 | 8 x 20 | 295 |
| IP5340 | 4×2,5 | 8 x 24 | 431 |
| IP5341 | 4×4 | 9 x 26 | 505 |
| IP5342 | 4×6 | 10 x 29 | 608 |
| IP5343 | 4×10 | 12 x 35 | 910 |
| IP5344 | 4×16 | 13 x 40 | 1225 |
| IP5345 | 4×25 | 15 x 46 | 1 763 |
| IP5346 | 4×35 | 16 x 53 | 2 210 |
| IP5347 | 4×50 | 19 x 61 | 3 054 |
| IP5348 | 4×70 | 22 x 74 | 4 429 |
| IP5349 | 4×95 | 24 x 79 | 5 367 |
A decade ago, photovoltaic (PV) systems...
Read
Safety is a top priority for all of…
Read
Fiber optic cables are essential for transmitting data…
Read