BiTcrane®(N)TSCGEWOEU-SR PLUS

Medium voltage, flexible power supply cable for reeling applications based on DIN VDE 0250-813

Industrial application Industrial application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
High flexibility High flexibility
Mechanical resistance Mechanical resistance
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Low operating temperature Low operating temperature
Explosion hazard area Explosion hazard area
Reeling cable Reeling cable

Basic

  • Type: Crane cables

Operating temperature

  • fixed installation from: -50°C
  • fixed installation up to: 80°C
  • flexible connections up to: 80°C

Max. permissible conductor temp.: 90 °C
Max. short-circuit temp. at conductor: 250 °C
De-rating factors: acc. to DIN VDE 0298-4

Max. tensile load on conductor: 20 N/mm²
Torsional stresses: ± 25 °/m
Bending radius: acc. to DIN VDE 0298-3
Min. distance with S-type directional changes: 20 x O.D.
Reeling speed: up to 240 m/min

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: rubber
  • Sheath type: rubber
  • Sheath color: red

Flame retardant

  • For a single insulated cable

Installation conditions

  • Flexible connections
  • Handling apllications

Environmental resistance

  • Oil resistant EN 60811-404
  • Increased mechanical resistance
  • UV resistance

Flexible reeling cable for power supply with cable guidance in different levels, e.g. reel axis in travel direction. Especially for high and extreme mechanical stress. For connection of large material handling machines in open pit mines, different crane types in harbours, shipyards, stacker/reclaimers in stockyards and other industrial areas.

BiTcrane®(N)TSCGEWOEU-SR PLUS 3.6/6 kV

Cat. no.

n x mm2Outer
diameter
min.-max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force
static/dynamic
[N]
BC000653×25+3×25/340-4324001125 / 1500
BC000663×35+3×25/343-4629401575 / 2100
BC000673×50+3×25/347-5035802250 / 3000
BC000683×70+3×35/351-5445003150 / 4200
BC000693×95+3×50/356-5956704275 / 5700
BC000703×120+3×70/359-6266905400 / 7200
BC000713×150+3×70/362-6578106750 / 9000
BC000723×185+3×95/369-7294608325 / 11100
BC000733×240+3×120/373-761170010800 / 14400
BiTcrane®(N)TSCGEWOEU-SR PLUS 6/10 kV

Cat. no.

n x mm2Outer
diameter
min.-max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force
static/dynamic
[N]
BC000803×25+3×25/342-4525701125 / 1500
BC000813×35+3×25/344-4730201575 / 2100
BC000823×50+3×25/348-5136702250 / 3000
BC000833×70+3×35/353-5647503150 / 4200
BC000843×95+3×50/357-6057704275 / 5700
BC000853×120+3×70/360-6368205400 / 7200
BC000863×150+3×70/365-6881506750 / 9000
BC000873×185+3×95/370-7395908325 / 11100
BC000883×240+3×120/374-771183010800 / 14400
BiTcrane®(N)TSCGEWOEU-SR PLUS 8.7/15 kV

Cat. no.

n x mm2Outer
diameter
min.-max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force
static/dynamic
[N]
BC000953×25+3×25/342-4525701125 / 1500
BC000963×35+3×25/344-4730201575 / 2100
BC000973×50+3×25/348-5136702250 / 3000
BC000983×70+3×35/353-5647503150 / 4200
BC000993×95+3×50/357-6057704275 / 5700
BC001003×120+3×70/360-6368205400 / 7200
BC001013×150+3×70/365-6881506750 / 9000
BC001023×185+3×95/370-7395908325 / 11100
BC001033×240+3×120/374-771183010800 / 14400
BiTcrane®(N)TSCGEWOEU-SR PLUS 12/20 kV

Cat. no.

n x mm2Outer
diameter
min.-max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force
static/dynamic
[N]
BC001103×25+3×25/349-5232601125 / 1500
BC001113×35+3×25/353-5639201575 / 2100
BC001123×50+3×25/357-6046302250 / 3000
BC001133×70+3×35/360-6356203150 / 4200
BC001143×95+3×50/365-6869304275 / 5700
BC001153×120+3×70/369-7280405400 / 7200
BC001163×150+3×70/372-7592006750 / 9000
BC001173×185+3×95/378-81109908325 / 11100
BC001183×240+3×120/383-861332010800 / 14400
BiTcrane®(N)TSCGEWOEU-SR PLUS 14/25 kV

Cat. no.

n x mm2Outer
diameter
min.-max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force
static/dynamic
[N]
BC002353×25+3×25/355-5839001125 / 1500
BC002363×35+3×25/357-6044201575 / 2100
BC002373×50+3×25/361-6451602250 / 3000
BC002383×70+3×35/366-6964203150 / 4200
BC002393×95+3×50/370-7375404275 / 5700
BiTcrane®(N)TSCGEWOEU-SR PLUS 18/30 kV

Cat. no.

n x mm2Outer
diameter
min.-max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force
static/dynamic
[N]
BC002473×25+3×25/358-6143101125 / 1500
BC002483×35+3×25/361-6448501575 / 2100
BC002493×50+3×25/366-6958502250 / 3000
BC002503×70+3×50/370-7370303150 / 4200
BC002513×95+3×50/373-7680604275 / 5700
Fiber Optic Cables – efficient methods of data transmission

Fiber Optic Cables – efficient methods of data transmission

Fiber optic cables, which gained popularity at the…

Read
Coaxial Cables. Impedance, Attenuation, Applications.

Coaxial Cables. Impedance, Attenuation, Applications.

A coaxial cable is a specialized type of…

Read
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read